Fiber Optic Cable
Short description:
PRODUCT DESCRIPTION
General introduction
  • This standard includes general optical and structural requirements for fiber optic cables containing 48 and 96 optical fibers produced by Recoin Joint Stock Company.
  • The optical fiber used is single mode - step refractive index and is made of high quality glass material according to recommendations ITU-T G.652.D and TCVN 8665: 2011.
WIRE SIGN
  • 96FO metal-sheathed fiber optic cable, Symbol: CKL1 – LT8 – 96FO
  • Metal sheathed fiber optic cable 48FO, Symbol: CKL1 – LT4 – 48FO
1. Cable structure
Structure description:
TênMô tả
Number of optical fibers48FO/96FO
Number of optical fibers in 1 loose tube12FO
Loose tubeMaterial: PBT (Polybutylene terephthalate)\nOuter diameter: ≥ 2.0 mm, always round
Liquid tube filling compoundThixotrophic Jelly
Filler tube (if any)PE plastic (or equivalent), no recycled plastic used, same size as loose tube, no defects
p1b1t6Material: FRP (Fiberglass Reinforce with Palstic)\nDiameter: ≥ 2.0 mm
Waterproof ingredientsWater Blocking Yarn
Waterproof tape and creates uniform roundness for cable cores (Water Blocking Tape)
Core braiding methodSZ reversible braid.
Made of Aramid fibers that are tightly bonded together to make it easy to distinguish from other components and ensure it is strong enough to strip the cable sheath.\nLocated under the corrugated steel tape."Cable Rip Cord (Ripcord Cord)"
Lớp bảo vệ cơ họcBăng thép nhăn, độ cao gợn sóng 0,5mm.
Độ dư sợi quangTối thiểu 1% so với chiều dài cáp ở khoảng nhiệt độ từ 20°C đến 30°C
Lớp vỏ ngoàiVật liệu: Nhựa HDPE màu đen Độ dày: 2,0 mm ± 0,1mm
1. Cable cover and reinforcement
  • The outer shell is made from 100% new high-quality HDPE material, contains black carbon that can withstand the impact of ultraviolet rays, contains antioxidants, is not capable of growing mold on the shell and has electrical insulating properties. Do not use recycled plastic.
  • The cable cover protects the cable core from mechanical impacts and external environmental influences during storage, installation and exploitation (water, temperature, chemicals, rodents...).
  • The cable sheath is guaranteed to be smooth, concentric, without joints, cracks, or holes; Uniform quality (no: rough, porous, contains air bubbles, splits, has blisters, defects, lumps), does not contain metal components, is flexible, sturdy, peels easily , do not stick too tightly to the cable core to dent the loose buffer tube when separating the shell.
  • Able to withstand high voltage: Minimum 20 kVDC or 10kVACrms with frequency from 50Hz to 60Hz; There is no phenomenon of ignition or cable sheath puncture after 5 minutes of testing.
  • The corrugated steel tape ensures cable protection against mechanical impacts and is rodent-proof; Using low carbon steel electroplated with chrome with a thickness after corrugated stamping ≥ 0.15mm, and coated with ethylene arcylic copolymer on both sides, coating thickness ≥ 0.04mm. Corrugated steel tape wraps along the entire SZ braided cable core with the overlap of the steel tape being at least 3mm. The outer diameter of the steel tape overlapping part is equal to the outer diameter of the wavy part.
  • 2. Specify the number and color of liquid tubes and the quantity of loose tubes and filler tubes
    The fiber color code complies with TIA/EIA-598-A standard
    The number, color of liquid tubes, and quantity of loose tubes and filler tubes comply with the provisions in the following table:
    Loose tubeCable core element (loose tube/filled tube)
    TT12345678
    BlueOrangeGreenBrownXámWhiteRedBlack
    Number of optical fibers48FO12121212PaddedPadded
    96FO12121212121212
    3. Specifications of optical fiber
    Optical and geometrical characteristics of single-mode optical fiber according to ITU-T G.652.D recommendations, coated with UV Cured crylate layer that is resistant to ultraviolet rays and meets the following specifications:
    TTTarget nameStandardMeasurement methods
    1Fiber Attenuation Coefficient (Attenuation Coefficent)≤ 0,35 dB/km ≤ 0,36 dB/km ≤ 0,21 dB/km ≤ 0,22 dB/kmIEC 60793-1-40
    2Dispersion coefficient≤ 3,5 ps/nm×km ≤ 18 ps/nm×kmIEC 60793-1-42
    3Polarization Mode Dispersion (PMD)IEC 60793-1-48
    4Wavelength with zero dispersion (λmin – λmax)1300nm ≤ λ0 ≤ 1324nmIEC 60793-1-42
    5Zere dispersion slope at point 0\n(Zere dispersion slope – S0max)≤ 0,092 ps/nm^2×kmIEC 60793-1-40
    6Cut–off wavelength λcc (Cut–off wavelength)≤ 1260nmIEC 60793-1-44
    7Loss when bending optical fiber at wavelength 1625nm (Marcro bending loss) with radius r = 30mm × 100 turns≤ 0,1 dBIEC 60793-1-47
    8Loss when bending optical fiber at wavelength 1625nm (Marcro bending loss) with radius r = 30mm × 100 turns9,2µm ± 0,5µmIEC 60793-1-45
    9Core concentricity error≤ 0,6µmIEC 60793-1-20
    10Cladding diameter125µm ± 1,0µmIEC 60793-1-20
    11Cladding noncircularity≤ 1 %IEC 60793-1-20
    12Primary coating diameter245µm ± 10µm 250µm ± 10µmIEC 60793-1-21
    13Point Discontinuity increases dramatically at wavelengths 1310nm and 1550nm (Point Discontinuity)≤ 0,05dBIEC 60793-1-40
    14Fiber tension≥ 0,69Gpa (100kpsi)IEC 60793-1-30
    15Fiber color codeTheo EIA/TIA-598
    16The primary shell uses a material that resists the effects of ultraviolet rays (acrylate), minimizing the impact of the external environment.
    17The primary shell before dyeing has a nominal diameter of 245µm ± 10µm, after dyeing it has a nominal diameter of 250µm ± 10µm using a durable ink over time. When applying, wipe off the gel around the fibers with 90° alcohol without discoloration
    18When welding is performed, the primary shell can be easily separated from the fiber without using chemicals and without affecting the fiber.
    4. Physical, mechanical and environmental properties
    Physical, mechanical and environmental tests (at wavelengths of 1310 and 1550nm):
    TTTarget nameTest methods and standards
    1Ability to withstand tensionIEC 60794-1-2-E1Fibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25%
    ResultFibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25%
    2Compression resistanceIEC 60794-1-2-E3Fibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components.
    ResultFibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components.
    5.3shock resist abilityIEC 60794-1-2-E4The fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB
    ResultThe fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB
    5.4Ability to withstand bendingIEC 60794-1-2-E6 (hoặc E11)The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB.
    ResultThe fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB.
    5.5Torsion resistanceIEC 60794-1-2-E7The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB;
    ResultThe fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB;
    5.6Heat resistanceIEC 60794-1-2-F1Attenuation gain: < 0.05 dB/km
    ResultAttenuation gain: < 0.05 dB/km
    5.7Test the flow of the filling compoundIEC 60794-1-2-E14The filler in the test sample does not fall or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall off.
    ResultThe filler in the test sample does not fall or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall off.
    5.8Waterproof abilityIEC 60794-1-2-F5Water does not penetrate through the test sample
    ResultWater does not penetrate through the test sample
    5.9Ability to withstand discharge voltageTCN 68-160:1998The cable cover is not punctured
    ResultThe cable cover is not punctured
    5.Mechanical properties and cable installation environment
    Physical, mechanical and environmental tests of the FTTx-LT-F8 subscriber line (at wavelengths of 1310nm, 1490nm and 1550nm).
    TTTargetsTest methods and standards
    1Ability to withstand tensionIEC 60794-1-2-E1Fibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25%
    ResultFibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25%
    2Compression resistanceIEC 60794-1-2-E3Fibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components.
    ResultFibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components.
    5.3shock resist abilityIEC 60794-1-2-E4The fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB
    ResultThe fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB
    5.4Ability to withstand bendingIEC 60794-1-2-E6 (hoặc E11)The fiber is not broken, the cable jacket is not cracked.\nIncreased loss: ≤ 0.1 dB.
    ResultThe fiber is not broken, the cable jacket is not cracked.\nIncreased loss: ≤ 0.1 dB.
    5.5Torsion resistanceIEC 60794-1-2-E7The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB;
    ResultThe fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB;
    5.6Heat resistanceIEC 60794-1-2-F1Attenuation gain: < 0.05 dB/km
    ResultAttenuation gain: < 0.05 dB/km
    5.7Test the flow of the filling compoundIEC 60794-1-2-E14The filler in the test sample does not flow or fall out or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall.
    ResultThe filler in the test sample does not flow or fall out or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall.
    5.8The filler in the test sample does not flow or fall out or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall.IEC 60794-1-2-F5Water does not penetrate through the test sample
    ResultWater does not penetrate through the test sample
    5.9Ability to withstand discharge voltageTCN 68-160:1998The cable cover is not punctured
    ResultThe cable cover is not punctured
    6. Physical, electromechanical and environmental characteristics of subscriber wires

    TT

    Specifications

    Targets

    1

    Maximum allowable load during installation  2.700N

    2

    Maximum allowable load when working  900N

    3

    Temperature range when installed-5oC ~ +65oC

    4

    Working temperature range-10oC ~ +65oC

    5

    Minimum bend radius when installed10 times the cable diameter

    6

    Minimum bend radius after installation20 times the cable diameter
    7. Tensile force of subscriber wire
  • The maximum allowable pulling force during construction of the subscriber line (in a short time) is at least 500N
  • The allowable tension during use is greater than 30% of the maximum tension during construction.
  • 8. Clearance and deflection
  • With a passing distance of ≤ 50m with a deflection of 1%.
  • With a passing distance of ≤ 50m with a deflection of 1%.
  • 10. Pack
  • Average length of subscriber line: 3000m
  • Subscriber wire is wrapped in a wooden cable drum (with a length of 3000m)
  • After completing the test measurements, the two ends of the coil are covered to make it waterproof
  • The cable drum surface is recorded with the following information
  • Manufacturer name: RECOIN
  • Cable type: FTTx-LT-F8 subscriber line
  • Number of optical fibers: 1F0/2F0/4F0
  • Customer name: VNPT
  • Cable length: 3000m
  • Date of manufacture: .............
  • Test day: ..............
  • Cable weight: ............kg
  • Weight of bobbin: ...........kg
  • The arrow points out the entire wire
  • KCS inspection mark when leaving the factory
  • 11. Other features
  • The subscription wire cover ensures solid protection of the wire core (heart tube) and twisted steel wire hanging in exploitation installations
  • When stripping/tearing apart the hanging wire, the steel core of the hanging wire or wire core should not be exposed.
  • Wire life >= 10 year
  • Document details Download here