Fiber Optic Cable
Short description:
PRODUCT DESCRIPTION
General introduction
- This standard includes general optical and structural requirements for fiber optic cables containing 48 and 96 optical fibers produced by Recoin Joint Stock Company.
- The optical fiber used is single mode - step refractive index and is made of high quality glass material according to recommendations ITU-T G.652.D and TCVN 8665: 2011.
WIRE SIGN
- 96FO metal-sheathed fiber optic cable, Symbol: CKL1 – LT8 – 96FO
- Metal sheathed fiber optic cable 48FO, Symbol: CKL1 – LT4 – 48FO
1. Cable structure
Structure description:
Tên | Mô tả | |
Number of optical fibers | 48FO/96FO | |
Number of optical fibers in 1 loose tube | 12FO | |
Loose tube | Material: PBT (Polybutylene terephthalate)\nOuter diameter: ≥ 2.0 mm, always round | |
Liquid tube filling compound | Thixotrophic Jelly | |
Filler tube (if any) | PE plastic (or equivalent), no recycled plastic used, same size as loose tube, no defects | |
p1b1t6 | Material: FRP (Fiberglass Reinforce with Palstic)\nDiameter: ≥ 2.0 mm | |
Waterproof ingredients | Water Blocking Yarn | |
Waterproof tape and creates uniform roundness for cable cores (Water Blocking Tape) | ||
Core braiding method | SZ reversible braid. | |
Made of Aramid fibers that are tightly bonded together to make it easy to distinguish from other components and ensure it is strong enough to strip the cable sheath.\nLocated under the corrugated steel tape. | "Cable Rip Cord (Ripcord Cord)" | |
Lớp bảo vệ cơ học | Băng thép nhăn, độ cao gợn sóng 0,5mm. | |
Độ dư sợi quang | Tối thiểu 1% so với chiều dài cáp ở khoảng nhiệt độ từ 20°C đến 30°C | |
Lớp vỏ ngoài | Vật liệu: Nhựa HDPE màu đen Độ dày: 2,0 mm ± 0,1mm |
1. Cable cover and reinforcement
2. Specify the number and color of liquid tubes and the quantity of loose tubes and filler tubes
The fiber color code complies with TIA/EIA-598-A standard
The number, color of liquid tubes, and quantity of loose tubes and filler tubes comply with the provisions in the following table:
Loose tube | Cable core element (loose tube/filled tube) | |||||||
TT | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Blue | Orange | Green | Brown | Xám | White | Red | Black | |
Number of optical fibers | 48FO | 12 | 12 | 12 | 12 | Padded | Padded | |
96FO | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
3. Specifications of optical fiber
Optical and geometrical characteristics of single-mode optical fiber according to ITU-T G.652.D recommendations, coated with UV Cured crylate layer that is resistant to ultraviolet rays and meets the following specifications:
TT | Target name | Standard | Measurement methods |
1 | Fiber Attenuation Coefficient (Attenuation Coefficent) | ≤ 0,35 dB/km ≤ 0,36 dB/km ≤ 0,21 dB/km ≤ 0,22 dB/km | IEC 60793-1-40 |
2 | Dispersion coefficient | ≤ 3,5 ps/nm×km ≤ 18 ps/nm×km | IEC 60793-1-42 |
3 | Polarization Mode Dispersion (PMD) | IEC 60793-1-48 | |
4 | Wavelength with zero dispersion (λmin – λmax) | 1300nm ≤ λ0 ≤ 1324nm | IEC 60793-1-42 |
5 | Zere dispersion slope at point 0\n(Zere dispersion slope – S0max) | ≤ 0,092 ps/nm^2×km | IEC 60793-1-40 |
6 | Cut–off wavelength λcc (Cut–off wavelength) | ≤ 1260nm | IEC 60793-1-44 |
7 | Loss when bending optical fiber at wavelength 1625nm (Marcro bending loss) with radius r = 30mm × 100 turns | ≤ 0,1 dB | IEC 60793-1-47 |
8 | Loss when bending optical fiber at wavelength 1625nm (Marcro bending loss) with radius r = 30mm × 100 turns | 9,2µm ± 0,5µm | IEC 60793-1-45 |
9 | Core concentricity error | ≤ 0,6µm | IEC 60793-1-20 |
10 | Cladding diameter | 125µm ± 1,0µm | IEC 60793-1-20 |
11 | Cladding noncircularity | ≤ 1 % | IEC 60793-1-20 |
12 | Primary coating diameter | 245µm ± 10µm 250µm ± 10µm | IEC 60793-1-21 |
13 | Point Discontinuity increases dramatically at wavelengths 1310nm and 1550nm (Point Discontinuity) | ≤ 0,05dB | IEC 60793-1-40 |
14 | Fiber tension | ≥ 0,69Gpa (100kpsi) | IEC 60793-1-30 |
15 | Fiber color code | Theo EIA/TIA-598 | |
16 | The primary shell uses a material that resists the effects of ultraviolet rays (acrylate), minimizing the impact of the external environment. | ||
17 | The primary shell before dyeing has a nominal diameter of 245µm ± 10µm, after dyeing it has a nominal diameter of 250µm ± 10µm using a durable ink over time. When applying, wipe off the gel around the fibers with 90° alcohol without discoloration | ||
18 | When welding is performed, the primary shell can be easily separated from the fiber without using chemicals and without affecting the fiber. |
4. Physical, mechanical and environmental properties
Physical, mechanical and environmental tests (at wavelengths of 1310 and 1550nm):
TT | Target name | Test methods and standards | |
1 | Ability to withstand tension | IEC 60794-1-2-E1 | Fibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25% |
Result | Fibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25% | ||
2 | Compression resistance | IEC 60794-1-2-E3 | Fibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components. |
Result | Fibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components. | ||
5.3 | shock resist ability | IEC 60794-1-2-E4 | The fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB |
Result | The fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB | ||
5.4 | Ability to withstand bending | IEC 60794-1-2-E6 (hoặc E11) | The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB. |
Result | The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB. | ||
5.5 | Torsion resistance | IEC 60794-1-2-E7 | The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB; |
Result | The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB; | ||
5.6 | Heat resistance | IEC 60794-1-2-F1 | Attenuation gain: < 0.05 dB/km |
Result | Attenuation gain: < 0.05 dB/km | ||
5.7 | Test the flow of the filling compound | IEC 60794-1-2-E14 | The filler in the test sample does not fall or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall off. |
Result | The filler in the test sample does not fall or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall off. | ||
5.8 | Waterproof ability | IEC 60794-1-2-F5 | Water does not penetrate through the test sample |
Result | Water does not penetrate through the test sample | ||
5.9 | Ability to withstand discharge voltage | TCN 68-160:1998 | The cable cover is not punctured |
Result | The cable cover is not punctured |
5.Mechanical properties and cable installation environment
Physical, mechanical and environmental tests of the FTTx-LT-F8 subscriber line (at wavelengths of 1310nm, 1490nm and 1550nm).
TT | Targets | Test methods and standards | |
1 | Ability to withstand tension | IEC 60794-1-2-E1 | Fibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25% |
Result | Fibers are not broken, cable sheath is not cracked.\nIncreased attenuation: ≤ 0.1 dB, elongation ≤ 0.25% | ||
2 | Compression resistance | IEC 60794-1-2-E3 | Fibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components. |
Result | Fibers are not broken, cable sheath is not cracked.\nIncreased loss: ≤ 0.1 dB\nCompression marks do not pose a danger to cable components. | ||
5.3 | shock resist ability | IEC 60794-1-2-E4 | The fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB |
Result | The fiber is not broken, the cable sheath is not cracked, and the steel band is not exposed.\nThe impact marks are considered normal.\nIncreased attenuation: ≤ 0.1 dB | ||
5.4 | Ability to withstand bending | IEC 60794-1-2-E6 (hoặc E11) | The fiber is not broken, the cable jacket is not cracked.\nIncreased loss: ≤ 0.1 dB. |
Result | The fiber is not broken, the cable jacket is not cracked.\nIncreased loss: ≤ 0.1 dB. | ||
5.5 | Torsion resistance | IEC 60794-1-2-E7 | The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB; |
Result | The fiber is not broken, the cable cover is not cracked.\nIncreased loss: ≤ 0.1 dB; | ||
5.6 | Heat resistance | IEC 60794-1-2-F1 | Attenuation gain: < 0.05 dB/km |
Result | Attenuation gain: < 0.05 dB/km | ||
5.7 | Test the flow of the filling compound | IEC 60794-1-2-E14 | The filler in the test sample does not flow or fall out or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall. |
Result | The filler in the test sample does not flow or fall out or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall. | ||
5.8 | The filler in the test sample does not flow or fall out or the contents of the filler leak out < 0.05g.\nThe optical fibers in the loose tube stay in place and do not fall. | IEC 60794-1-2-F5 | Water does not penetrate through the test sample |
Result | Water does not penetrate through the test sample | ||
5.9 | Ability to withstand discharge voltage | TCN 68-160:1998 | The cable cover is not punctured |
Result | The cable cover is not punctured |
6. Physical, electromechanical and environmental characteristics of subscriber wires
TT | Specifications | Targets |
1 | Maximum allowable load during installation | 2.700N |
2 | Maximum allowable load when working | 900N |
3 | Temperature range when installed | -5oC ~ +65oC |
4 | Working temperature range | -10oC ~ +65oC |
5 | Minimum bend radius when installed | 10 times the cable diameter |
6 | Minimum bend radius after installation | 20 times the cable diameter |
7. Tensile force of subscriber wire
8. Clearance and deflection
10. Pack
11. Other features
Document details Download here